Zozen Boiler

TEL: 400-161-0099

Inquire Now
Home / Product Center / Thermal Fluid Heater / YY(Q)W Horizontal gas Thermal fluid (hot oil) heater
YY(Q)W Horizontal gas Thermal fluid (hot oil) heater
YY(Q)W Horizontal gas Thermal fluid (hot oil) heater
  • ModelYY(Q)W
  • FuelNatural gas, gas, biogas
  • Capacity0.7~14.0 MW
  • Pressure0.8~1.0 MPa
  • ApplicationPetrochemicals.Textiles.Printing and dyeing.Plastics.Rubber.Food processing.Wood processing.Asphalt heating.Carton production
Inquiry Now
7*24h Online 400-161-0099
Case Service
Product Detail Product introduction

  Gas-fired heat-conducting oil boilers can operate stably even under low-pressure environment, and the temperature can be set by computer. The operation of the boiler is relatively stable, the control of the temperature is more accurate, and the thermal efficiency can reach more than 90%. Horizontal gas heat conduction oil boiler is an ideal heating equipment. It is widely used in various industries.

  The heating surface of the boiler body of gas-fired oil-conducting oil furnace is compact in structure, and the heating surface is composed of inner and outer densely arranged disks. The inner coil tube is a radiation heating surface, and the outer surfaces of the outer coil tube and the inner coil tube constitute a convection heating surface. The boiler consists of an upper body and a lower combustion chamber, which are assembled on site. After the combustion is fully burned in the combustion chamber, most of the heat is absorbed by the radiation heating surface. The high-temperature flue gas enters the convection heating surface for heat exchange. After exiting the boiler, the air required for boiler combustion is heated in the air preheater, and then passes through the dust collector. The induced draft fan sends the flue gas to the chimney for discharge into the atmosphere.

  The principle of the gas-fired oil-conducting oil furnace: Generally, natural gas is used as the fuel, and the heat-conducting oil is the heat carrier. The circulating oil pump is used to force liquid-phase circulation. After the heat energy is transferred to the heat-generating equipment, the heat carrier is then returned to the reheated DC-type special industrial furnace.

Basic parameters The basic parameters
Basic technical parameters of YY(Q)W Horizontal gas Thermal fluid (hot oil) heater
Model YY(Q)W-700Y(Q) YY(Q)W-1000Y(Q) YY(Q)W-1200Y(Q) YY(Q)W-1400Y(Q) YY(Q)W-1800Y(Q) YY(Q)W-2400Y(Q) YY(Q)W-2800Y(Q) YY(Q)W-3500Y(Q)
Rated heating load(KW) MW/h 0.7 1.0 1.2 1.4 1.8 2.4 2.8 3.5
x104kcal/h 60 80 100 120 160 200 240 300
Desigen working temperature(≤℃) 320 320 320 320 320 320 320 320
Rated working pressur(MPa)
0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8
Heat efficiency(≥%) 88 88 88 88 90 90 90 90
System installed capacity(KW) 18 18 35 35 56 56 66 75
Maximum transport dimensions(mm) 长 L 3550 3800 3800 4250 4900 5250 6050 6650
宽 W 1680 1680 2000 2000 2200 2450 2450 2550
高 H 2050 2050 2400 2550 2600 2950 2950 3000
(kg)
Weight of biggest part for transportation
4220 5000 5450 6400 8500 11200 12500 14000
Model YY(Q)W-4200Y(Q) YY(Q)W-4600Y(Q) YY(Q)W-6000Y(Q) YY(Q)L-7000Y(Q) YY(Q)L-8200Y(Q) YY(Q)L-9400Y(Q) YY(Q)L-10500Y(Q) YY(Q)L-12000Y(Q) YY(Q)L-14000Y(Q)
Rated heating load(KW) MW/h 4.2 4.6 6.0 7.0 8.2 9.4 10.5 12 14
x104kcal/h 360 400 500 600 700 800 900 1000 1200
Desigen working temperature(≤℃) 320 320 320 320 320 320 320 320 320
Rated working pressure(MPa) 0.8 0.8 0.8 0.8 0.8 1.0 1.0 1.0 1.0
Heat efficiency(≥%) 90 90 90 90 90 90 90 90 90
System installed capacity(KW) 95 95 140 140 140 200 200 240 300
Maximum transport dimensions(mm) 长 L 6850 6950 7200 8000 8500 9500 10500 12350 13500
宽 W 2700 2850 3250 3550 3650 3800 3800 3800 4000
高 H 3150 3310 3900 3950 4000 4000 4000 4000 4200
(kg)Weight of biggest part for transportation 15800 18000 24500 28500 33000 39000 55000 60000 65000
 
Note: Technical parameters are subject to change without notice.
Advantage The working principle of
  • Has a very thick thermal insulation layer to minimize heat loss;
  • Thickened boiler heat-resistant steel pipe is a guarantee of boiler safety, advanced technology and procedures ensure the safety and stability of the boiler, automatic flame alarm device, automatic control of boiler pressure and temperature;
  • The reasonable consistency of the boiler structure, the flow rate of the hot oil and the flow rate ensures that the tube does not burst due to carbon deposition, which not only ensures the safety of the boiler, but also prolongs the service life of the oil.
  • According to the user's requirements, it can be realized that a boiler can simultaneously output different temperature heat transfer oil to heat the heated body;
  • According to the user's requirements for different occasions, all equipment will be installed together and installed in the factory;
  • Horizontal boiler, neat appearance, generous, easy to operate, simple;
  • Controller centralized control, set automatic detection, control, chain alarm in one, boiler operation without duty;
  • The horizontal three return strokes are all back-structures. Adding energy savers is equivalent to a four-city structure. Higher thermal efficiency
  • The boiler has a large volume of water and a large amount of steam, reducing the frequent start-stop of boilers and extending the service life of burners and electronic components;
  • Fire tube structure, no squib occurrence, safer use;
  • Before and after the smoke box can be opened, boiler repair is very convenient.
Case Successful cases
Project: Danyang Auxiliary Chemical Plant & 5 million kcal YY(Q)W Thermal Fluid Heater Project Customer: Danyang Auxiliary Chemical Co., Ltd. Company profile: Domestic high-level auxiliary chemical plant Project type: Complete Project (Supply boiler, auxiliary equipment, installation and commissioning) Address: Dangyang Zhenjiang Matched boiler: YY(Q)W-6000Y(Q) Boiler Medium: OIL Rated evaporation: 5million kcal
Cooperative Client: Shandong Honghai Chemical Co., LTD Type:Gas/Oil-Fired Thermal Fluid Heater Model: YQL-17500Q Thermal Fluid Heater Thermal Power: 15 million kcal Location: Shandong Application: Petrochemical Industry
Cooperative Client: Pteris Global (Vietnam) Co., LTD Type:Coal-Fired Thermal Fluid Heaters Model: YLW-17500M Thermal Fluid Heater Thermal Power: 15 million kcal Location: Vietnam Application: Mechanical equipment
News Related to recommend