Zozen Boiler

TEL: 400-161-0099

Inquire Now
Home / Product Center / Steam Boiler / DZL Coal-fired steam boiler
DZL Coal-fired steam boiler
DZL Coal-fired steam boiler
  • ModelDZL
  • FuelIntermediate bituminous coal, anthracite
  • Capacity0.7~14.0 MW
  • Pressure0.7/1.0/1.25/1.57/1.6/2.45 Mpa
  • ApplicationLarge, medium and small-sized industrial and mining enterprises use steam and live heating
Inquiry Now
7*24h Online 400-161-0099
Case Service
Product Detail Product introduction

  The DZL series quick-loading boiler is a horizontal three-pass fire hose chain grate boiler, which uses medium-sized bituminous coal and anthracite. The boiler body is longitudinally arranged with a single drum. The threaded tobacco pipes are arranged in the drum to form a convection heating surface, and the drum and the water cooling walls on both sides constitute the radiation heating surface of the furnace. The combustion equipment uses light chain grate; The electric control realizes governor stepless speed regulation, limit parameter alarm and chain protection.

Basic parameters The basic parameters
Basic technical parameters of DZL Coal-fired steam boiler
 
Specification DZL1-0.7-AII
DZL1-1.0-AII
DZL0.7-0.7/95/70-AII
DZL2-1.0-AII
DZL2-1.25-AII
DZL2-1.57-AII
DZL2-2.45--AII
DZL1.4-0.7/95/70-AII
DZL4-1.25-AII
DZL4-1.57-AII
DZL4-2.45--AII
DZL2.8-0.7/95/70-AII
DZL6-1.25-AII
DZL6-1.6-AII
DZL4.2-1.0/115/70-AII
DZL10-1.25-AII
DZL10-1.6-AII
DZL7-1.0/115/70-AII
DZL15-1.25-AII
DZL15-1.6-AII
DZL10.5-1.0/115/70-AII
DZL20-1.25-AII
DZL20-1.6-AII
DZL14-1.0/115/70-AII
( t/h/MW)Rated evaporation capacity(supply heat) 1/0.7 2/1.4 4/2.8 6/4.2 10/7 15/10.5 20/14
(MPa)Rated pressure 0.7/1.0/0.7 1.0/1.25/1.57/2.45/0.7 1.25/1.57/2.45/0.7 1.25/1.6/1.0 1.25/1.6/1.0 1.25/1.6/1.0 1.25/1.6/1.0
(℃)Rated Steam temperature /Output water  temperature 170/184/95 184/194/204/225/95 194/204/225/95 194/204/115 194/204/115 194/204/115 194/204/115
(℃)Water supply temperature( return water temperature) 20/70 20/70 20/70 20/70 60/70 60/70 60/70
Heating area proper 32.4 59.3 89.16 126.7 251 380.8 470.7
(㎡)Economizer 12.51 28.16 38.5 78.5 174.4 174.4 377.6
(㎡)Effective area of great 2.05 3.7 5.3 8.32 12 17.38 21
Fuel available AII
二类烟煤 Coal
Fuel consumption 151 302 600 888 1447 2170 2894
(%)Thermal efficiency 79 79 79 79 79 79 81.45
(t)Weight of bigest part for transportation 13 22 25 23 29 20 23
(m)(L×W×H)Overall dimension of boiler assembled 5.2×2×2.9 5.8×2.5×3.5 6.3×2.6×3.6 7.3×3.2×3.6 7.2×3.3×3.6 8.8×3.7×3.7 9.7×3.4×3.7
(m)(L×W×H)Overall dimension of boiler assembled 6×3.5×4.1 6.0×3.9×5 7.2×4×4.9 8.0×5.1×6 8.2×6×6.5 10.2×6.7×8.6 13.5×7.4×8.7
 
Note: Technical parameters are subject to change without notice.
Advantage The working principle of
  • Compact structure, volume gradient, infrastructure investment province;
  • Adding coal and slag mechanization;
  • Boiler output is sufficient and efficient;
  • To avoid bulging defects: the riser tube is pulled to the hearth on the two sides of the tank, and then the bottom of the drum is covered with the bottom of the drum covered with thermal insulation material to form the heating surface of the furnace roof. The novel furnace structure successfully solves the problem. The bottom of the cylinder is directly subjected to high-temperature flame radiation to avoid "bullet" defects;
  • Good for the combustion of inferior coal: The arched design of the DZL chain grate coal-fired boiler adopts the latest scientific research results from the “National Science and Technology Progress Second Prize of Xi’an Jiaotong University”. The rear arch is low and long, the exit section is anti-tilt, the front arch angle is 45° and the rear The arches respond to each other, forming an inverted "α" flame, which is beneficial to the combustion of inferior coal, and the adaptability of coal is strong;
  • Prevent grate leakage: design push-pull gate cleaning device, gate heat-resistant cast iron finishing seal structure, thus effectively preventing secondary combustion deformation and grate leakage;
  • To avoid cracks in the tube sheet: the two-wing flue is set to allow the flue gas to enter the front smoke box smoothly, so that the temperature of the front tube sheet is the same and lower than 600°C, to avoid the DZL chain grate coal-fired boiler from generating heat due to temperature stress. Cracked board.
Case Successful cases
Project: Danyang Auxiliary Chemical Plant & 5 million kcal YY(Q)W Thermal Fluid Heater Project Customer: Danyang Auxiliary Chemical Co., Ltd. Company profile: Domestic high-level auxiliary chemical plant Project type: Complete Project (Supply boiler, auxiliary equipment, installation and commissioning) Address: Dangyang Zhenjiang Matched boiler: YY(Q)W-6000Y(Q) Boiler Medium: OIL Rated evaporation: 5million kcal
Cooperative Client: Shandong Honghai Chemical Co., LTD Type:Gas/Oil-Fired Thermal Fluid Heater Model: YQL-17500Q Thermal Fluid Heater Thermal Power: 15 million kcal Location: Shandong Application: Petrochemical Industry
Cooperative Client: Pteris Global (Vietnam) Co., LTD Type:Coal-Fired Thermal Fluid Heaters Model: YLW-17500M Thermal Fluid Heater Thermal Power: 15 million kcal Location: Vietnam Application: Mechanical equipment
News Related to recommend